-
Set of LED pen-light: green, red, yellow. Non-glare lights, useful to perform: corneal reflex, cover test, ocular motility, fixations, diagnostic and training procedures. Sold in set of 3 Vision Light. Batteries (1.5 V) are not enclosed Item #: E/VL
-
The Anti-Suppression BINGO Game Set was designed to be a reward activity at the end of a therapy session, but is also a great take home game for home therapy that can be played by the whole family! Just like regular BINGO, the game is played by drawing number balls and marking the player BINGO cards to get five numbers in a row vertically, diagonally, or horizontally. However, this set comes with special BINGO cards with numbers that disappear when viewed thru the red filter on the Bernell Red/Green glasses. Item #: BASGS1
-
20/200 to 20/10 size. 22-1/2" x 11" Item #: BC1243
-
Optokinetic Drum Ped 10 1/2' H x 8" Diameter Accurately test for acuity when rotated 8 to 10 RPMs at different reading distance. 10" long x 8" diameter Has Animals and Shapes Item #: DAL301
-
CRT Card Test Specifically designed for computer operators who require corrective multi-focal eyewear. Card may be placed at different heights and distanced to simulate the complete computer screen. Card is printed two sides -one side shows a computer screen with AOL. The other (Pictured) shows a Microsoft Word document with different fonts. Simulates a 15" computer monitor with shiny screen. has intentional errors to show red/green highlights.
-
Lea SYMBOLS® 15 Line Folding Distance Chart For screening or testing individuals beginning at age 2 1/2. Proportionally-spaced lines; line sizes range from 20/200 to 20/8 (6/60 to 6/2.4) equivalent. 50% spaced rectangle (Massachusetts Visual Acuity Test format) with line sizes from 20/100 to 20/8 (6/30 to 6/2.4) equivalent. Has a hole for hanging the chart on the wall.
-
Two mirrored sides septum, frontally and non-symmetrically set, is recommended for binocular training; antisuppressive and fusional activities; central-peripheral instrument applied in amblyopia. Easy to teach figure-ground, therapy and brain injury neuro-optometric rehabilitation (neglect).
-
Build anti-suppression in all areas – horizontal zones, vertical zones, specific quadrants, fine details, gross targets, variable sizes and orientations. For use with Bernell-O-Scope™ (10 cards) Item #: SMS
-
An affordable Risley Prism that you can use for testing. This prism allows variable prism demand up to 30PD. A prism before each eye can increase the demand of 60PD. The prism is approximately 1" diameter. Item #: ARPHH30
-
FLIPPER CASE INCLUDED. Professional level six piece set features plus/minus powers in 0.25, 0.50, 1.00, 1.50, 2.00 and 2.50 diopters. Deluxe black carrying case or the economy flipper holder included. Specify which you prefer. Flippers come with colored handle covers. Your account must be registered as a healthcare professional or a school/government in order to purchase this product.Item #: BC1270SET
-
Same great test as before, but with a new and improved package! One of only two color vision tests validated and required for Naval Aviators. ColorDx is new brand identity for the proven Waggoner six confusion-color strategy used by physicians, Ophthalmologists, Optometrists, and nurses worldwide. This military grade test is used by the US Army and for FAA annual flight physicals requiring color vision testing and has been independently validated by both academic institutions and military services. This new edition features enhanced digital colorimetery production methods, durable page and binding materials, and magnetic light-protective storage case. The ColorDx Standard 24 is designed and licensed from color vision expert Dr. Terrace Waggoner and is the newest edition of the Waggoner PIP-24 (PIPIC 24).
-
Features both upper and lower case letters to test near visual acuity in low vision patients. Appropriate starting high plus add power or magnifier power is indicated to the right of the line of copy the patient is able to read.
-
Bernell Red/Green Random Dot Variable Tranaglyph Square, Circle and Triangle Targets Now you can train using high levels of binocular skills. This slide can allow those with high amounts of esophoria or exophoira to experience random dot 3-D pictures for the first time. Use with our R/G flipper and get even more flexibility in training. (*Pictured with Sided Holder, not included)
-
7-1/2" x 5-1/2" Non-Variable Polarized vectograms ensure testing and training at actual distances. Vectograms stabalize fusion and steropsis, eliminate suppression and develop simultaneous vision. Used in monocular, binocular, pursuit and saccdic training, vectograms help correct and prevent anomalies involving projection and hand-eye coordination. Ideal for use with Bernells Dual Polachrome™ Trainer
-
These photographs come on heavy-duty 8-1/2" x 11" cardstock for durability. There are activity suggestions printed on the back of each card. Some photos are identical in everything except the type of vergence demand or the amount of vergence demand. These were designed for the offices who work with just noticeable differences (JND) with their patients. Item #: HDSPVP
-
Phoria Cards Test vertical and horizontal muscle balance at near and far. Used with Maddox Rod and Penlight. Referral considerations indicated on cards for imbalance beyond certain prism diopters or balance beyond specified esophoria and exophoria ranges. Shows phoria to parents!Item #: BC1209+
-
Variable Tranaglyph™ Kit (600 Series) Appropriate for a wide range of problems including strabismic and non-strabismic orthoptics. Fusional convergence/divergence range is from ortho to 30PD, 10.5" x 5.5" red/green targets are on transparent vinyl. Use with Polachrome Trainer as a cost-effective alternative to Polaroid vectograms. Item #: BC600K+
-
Suitable for testing very small children (2 1/2 to 5) as well as adults. Three plates for screening, 3 for diagnostic. Kit includes seven plates and red/green glasses.
-
Adult LEA NUMBERS® chart for ETDRS Illuminated light boxes. Fits all existing ETDRS cabinets including both the ESV3000 and ESC2000. LEA NUMBERS® ETDRS chart contains optotypes in proportionally spaced (logMAR) lines; lines range from 20/200 to 20/8 (6/60 to 6/2.4) equivalent, 0.10 to 2.50. Fits in ESV3000 ETDRS illuminated cabinet.
-
The new clear fixation paddle is 12" x 12" made of clear polycarbonate. Uses targets with cling material which adheres and removes easily from the front or back of the paddles by adhesion forces.
-
Set for Children Case with yoked rotating prisms for children. The set includes: 4 empty children's frame, 2 red and 2 blue. Plastic frame with nasal anatomical fit for children and adjustable elastic. Central screw for locking and unlocking the prisms. A pair of high quality plastic prisms for each power: 1, 2, 3, 5, 8, 10, 15, 20 PD. The power is cut on the prism's surface near the apex together with tactile notch. Item #: E/RYPSETC
-
Flipper features two sets of lenses to alternate demand. Used with Vectograms or Tranaglyphs to reverse Base-In/Base-Out demands. Item #: BC1270RGP
-
A Hand Held instrument to Measure a Maddox Phoria. This tests for anisophorias, vertical and horizontal, in all positions of gaze in real space instead of behind of phropter. Scale from 0 to 10 PD 25mm Item #: BC1211
-
Sized to fit over our Adult Optokinetic Drum (DAL300) this vinyl sheet is used to test for the optokinetic reflex. The banner has child interest targets similar to our DAL301. Can be rolled up for easy storage. Clear end pieces hold banner from curling. Washable plastic material similar to window shade. Velcro on backside of the banner allows for easy attachment around the Adult Optokinetic Drum (DAL300). Item #: OKNADP1
-
This much requested Near Acuity Card was originally developed by the American Optometric Association.
-
Vectographic Projector Slide Pediatric Slide This pediatric projector slide test depth perception and binocularity under distance conditions. The top portion of each slide is a standard non-vectographic projector slide. The bottom portion is a vetographic slide that contains suppression control targets, a distance stereo acuity test, fixation disparity and binocular balance. Slide fits most AO and Marco projectors, and there are adaptable to a 10' or 20' lane. REQUIRES POLARIZING SCREEN.
-
The Spatial Board was suggested by Dr. Streff as a way of quantifying and recording spatial localization shifts with patients. Dr. Kraskin utilized similar assessments of a patient's spatial localization in order to determine the amount and direction of yoked prisms to prescribe. The VTE Spatial Localization Board is designed for clinical efficiency to allow the behavioural optometrist to quickly assess a patient's spatial localization in real space and time; determine x, y and z axis spatial warps in 9 primary meridians; record patient responses for pre and post test data (especially good for documenting mid-line shifts in TBI and strabismic patients) and quantify immediate effects of lenses and prisms.
-
Basic Vertical Dr. Only Starter for any patient into fusion, anti-suppression and ranges of fusion. Set of 10 Cards For use with Bernell-O-Scope™ Item #: SMBV
-
Fits into the standard 38 mm eyewell of the Bernell-O-Scope or any standard trial lens frame. Each prism yields 20 PD for a total of 40PD. Now you can set any amount of BI, BO, or vertical prism into the stereoscope to do training procedures. May be used for distance training by removing the cardholder. Item #: ARPHH20
-
Red/Green Flippers Quality, four-well flipper bar features two alternating sets of red and green lenses. Reverses Base-In/Base-Out demand with each flip. Item #: BC1270RG
-
Same great test, but in a new and improved package! The ColorDx Pediatric 15 is the newest version of Color Vision Testing Made Easy or CVTME. As the Gold Standard pediatric assessment of color deficiencies or color blindness See The Multi-Ethnic Pediatric Eye Disease Study published by the AAO, CVTME™ is used in over 40 countries and has been validated for illiterates at the US Special Olympics. Featuring the proven Waggoner six confusion-color strategy, the pediatric test is used in a broad range of settings: pediatrics, eye physicians, school nurses, and many other disciplines of health care, in any language, world-wide. This easy to administer test features both hidden and non-hidden shapes that allow for positive reinforcement even while testing color deficient children by allowing successful answers on most targets. This success-reinforced strategy is also useful for assessment of malingering. Designed by color vision expert Dr. Terrace Waggoner, this new edition features enhanced digital colorimetery production methods, durable page and binding materials, and magnetic light-protective storage case and enhanced digital colorimetery production method and durable page materials and binding. Brilliantly simple to take, easy to score and just plain fun for children.
-
Projector Slide Replacements MultiAcuity Projector Slide Letter Acuity, Tumbling "E", Allen Figure Test This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
-
These offer excellent cancellation with no ghost images. These fixed demand targets provide flat fusion from 1-3 prism diopters, 2nd & 3rd degree fusion from 4-28 PD. BI & BO therapy is possible using a R/G flipper or switching the lenses in the goggles. (Set of 5 cards and one R/G Flipper)
-
7-1/2" x 5-1/2" Non-Variable Polarized vectograms ensure testing and training at actuall distances. vectograms stabalize fusion and steropsis, eliminates suppression and develop simulatneous vision. Used in monocular, binocular pursuit and saccadic training, vectograms help correct and prevent anomalies involving projection and hand eye coordination. Ideal for use with Bernell's Dual Polachrome™ Trainer
-
A good binocular screening device. Performed at a distance of 40 cm with a target of 20/30. Most normal patients can cycle between these prims 15/minute. Those with difficulty should be more thoroughly tested. 12D Base-Out and 3D Base-In. Prism is 1.5 inches square. Item #: G1110+
-
New 3D Modeled Variable Tranaglyph. Comparable to the popular Quoit Vectogram.