-
Worth 4-Dot Test Flashlight Used for testing and training of fusion, suppression, and/or diplopia. Red/Green goggle included. Requires 2 C batteries (not included).
-
This much requested Near Acuity Card was originally developed by the American Optometric Association.
-
Vectographic Projector Slide Pediatric Slide This pediatric projector slide test depth perception and binocularity under distance conditions. The top portion of each slide is a standard non-vectographic projector slide. The bottom portion is a vetographic slide that contains suppression control targets, a distance stereo acuity test, fixation disparity and binocular balance. Slide fits most AO and Marco projectors, and there are adaptable to a 10' or 20' lane. REQUIRES POLARIZING SCREEN.
-
Two mirrored sides septum, frontally and non-symmetrically set, is recommended for binocular training; antisuppressive and fusional activities; central-peripheral instrument applied in amblyopia. Easy to teach figure-ground, therapy and brain injury neuro-optometric rehabilitation (neglect).
-
Versatility, quality
Patients present a diverse range of eye conditions for you to evaluate and threat. With Tango Reflex™ from Ellex, you can expand the scope of care you’re able to provide, and all at the absolutely highest standard of safety and efficacy. -
The Lang Fixation Cubes have been designed by J. Lang for the assessment of eye fixation, motility, accommodation, convergence, for cover test, and to prepare the child for testing with the Lang-Stereotest® or the Lang-Stereopad®.
5 child-friendly objects are presented on the side and the top of the cube. Some of them are also included in the two versions of the Lang-Stereotest® and of the Lang-Stereopad®, and on the Lang Fixation stick.
The Cube has a red handle.
Each turn of the cube shows a new object. The star on the top side and the other objects can also be used for the test of convergence.
-
Eye Cubed™ features real time imaging, advanced movie mode, real-time image enhancement, and a range of self-calibrating "best fit" probes.Customized Configuration to Best Meet Your Needs
With customized configuration of A-Scan and B-Scan modes, Eye Cubed™ covers all of your diagnostic ultrasound needs for both the posterior and anterior segments. Pre-op or post-op, A-Scan or B-Scan, retina or anterior segment: whatever your focus, Eye Cubed™ shows you more, in more detail, than any other device of its kind.High Resolution Goes Ultra
Eye Cubed’s 40 MHz UBM mode allows you to view anterior structures such as the cornea, iris, ciliary body, crystalline and intraocular lens more clearly than ever before. Whether determining the sulcus-to-sulcus measurement for accurate ICL sizing or the angle for potential angle closure and possible YAG laser iridotomy, Eye Cubed’s 40M Hz UBM mode is the gold-standard in high-resolution ultrasound.Essential Technology for Your Practice
Even in an era of high-tech OCT scanning and digital imaging, ultrasound is the only means to obtain a crucial view of the posterior segment when there is a dense cataract or vitreous hemorrhage in the eye – making it one of the most fundamental diagnostic tools in ophthalmology. Detection of disorders like posterior vitreous detachment (PVD) in opaque ocular media is easily achieved with B-Scan ultrasound.Innovative Imaging
Since acquiring Sacramento-based ophthalmic ultrasound pioneers Innovative Imaging Inc. in 2006, Ellex has been working hard to provide ever-increasing value to our Eye Cubed customers – and to develop our ultrasound technology platform. With the support of personalized, clinical ultrasound applications training by expert ecographers, Eye Cubed™ offers a total solution for your practice – and for your patients.Ophthalmic Edge
Visit the comprehensive online diagnostic teaching tool created by Yale Fisher, MD, to access lectures, monographs and cases studies covering a range of diagnostic technologies, including ultrasound and OCT. -
Everyone who has anything to do with the prescription of eyeglasses has heard of OCULUS Universal Trial Frames. Function
- Space for a total of 10 trial lenses of 38 mm diameter
- PD range from 46-80 mm
- Adjustable temple tilt and length
- Smooth axis adjustment
- CVD scale
-
Vision Training Starter Set VTE Case designed to provide a large selection of products useful in testing and training the most common vision training problems. Item #: E/VTSET
-
Morgenstern Color Fusion Cards - Convergence A Dr. Only Used with Bernell-O-Scope™ CONVERGENCE A. TRADITIONAL VT FOR FUSION RANGES & JUMP DUCTIONS WITH COLORFUL TARGETS. INCREASE IN DEMAND AND RANGE OF FLEXIBILITY. Item #: SMCA
-
Fits into the standard 38 mm eyewall of the Bernell-O-Scope™ or and standard trial lens frame. Each prism yields 20 PD for a total of 40PD. Now you can set any amount of BI, BO, or vertical prism into the stereoscope to do training procedures. May be used for distance training by removing the cardholder. It may also be used with the new Bernell 3-D videos. Item #: ARPHH20S
-
Improve vertical or horiontal fusional reserves. Dispense to patients wearing vertical prism or with low fusional reserves. Does not fit in Slide Illuminators. Used with the vertical mini-vecto kit (BC275MVK) and with the horizontal Mini-Vecto Kit(BC216MVK) Item #: BC29