Bernell

//Bernell
  • Stereophotos
    These photographs come on heavy-duty 8-1/2" x 11" cardstock for durability. There are activity suggestions printed on the back of each card. Some photos are identical in everything except the type of vergence demand or the amount of vergence demand. These were designed for the offices who work with just noticeable differences (JND) with their patients. Item #: HDSPVP
  • Phoria CardPhoria Card 1
    Phoria Cards Test vertical and horizontal muscle balance at near and far. Used with Maddox Rod and Penlight. Referral considerations indicated on cards for imbalance beyond certain prism diopters or balance beyond specified esophoria and exophoria ranges. Shows phoria to parents!
    Item #: BC1209+
  • Variable Tranaglyph Slide - Bunny (600 Series)Fixed Demand Tranaglyph Kit
    Variable Tranaglyph™ Kit (600 Series) Appropriate for a wide range of problems including strabismic and non-strabismic orthoptics. Fusional convergence/divergence range is from ortho to 30PD, 10.5" x 5.5" red/green targets are on transparent vinyl. Use with Polachrome Trainer as a cost-effective alternative to Polaroid vectograms. Item #: BC600K+
  • Lea Symbols Pocket Near Card
    Pediatric near vision card featuring LEA Symbols pediatric symbols for testing children or illiterate adults at 16" (40 cm). It's small size makes it easy to carry or store. Front side contains proportionally-spaced lines in logarithmic progression with line sizes ranging from 20/400 to 20/10 (6/120 to 6/3) equivalent. The reverse side features pediatric symbols in 50% spaced rectangle (Massachusetts Visual Acuity Test format). Line sizes range from from 20/100 to 20/16 (6/30 to 6/4.8).
  • Lea Numbers Pocked Sized Near Card
    This test is designed for testing patients' visual acuity during rounds and in similar situations with a need for quick testing. The test has proportionally spaced (logMAR) lines on one side and tightly crowded lines (50% spacing) on the reverse side Line sizes from 20/400 to 20/10 (6/120 to 6/3) equivalent, 0.05 to 2.00. 3.75" x 6.25" (9.5 cm x 15.9 cm).
  • Full Color Aperture Rule Cards
    Aperture Rule™ Set (12 Stereoscope sized cards) These cares are more complex and require more detail demand. They build flexibility, resiliency, attention to detail and reduction of visual fatigue. These cards contain large quantities of details and build large ranges of fusion (leading to high amounts of prism diopters of 'Base Out' and 'Base In' fusion ranges) 12 Cards
  • Yoked Rotating Prism - Child Size
    Set for Children Case with yoked rotating prisms for children. The set includes: 4 empty children's frame, 2 red and 2 blue. Plastic frame with nasal anatomical fit for children and adjustable elastic. Central screw for locking and unlocking the prisms. A pair of high quality plastic prisms for each power: 1, 2, 3, 5, 8, 10, 15, 20 PD. The power is cut on the prism's surface near the apex together with tactile notch. Item #: E/RYPSETC
  • Bernell Red/Green and Polarized Combo Flipper
    Flipper features two sets of lenses to alternate demand. Used with Vectograms or Tranaglyphs to reverse Base-In/Base-Out demands. Item #: BC1270RGP
  • Phoria Measure
    A Hand Held instrument to Measure a Maddox Phoria. This tests for anisophorias, vertical and horizontal, in all positions of gaze in real space instead of behind of phropter. Scale from 0 to 10 PD 25mm Item #: BC1211
  • Pediatric OKN Banner Adapter 1Pediatric OKN Banner Adapter
    Sized to fit over our Adult Optokinetic Drum (DAL300) this vinyl sheet is used to test for the optokinetic reflex. The banner has child interest targets similar to our DAL301. Can be rolled up for easy storage. Clear end pieces hold banner from curling. Washable plastic material similar to window shade. Velcro on backside of the banner allows for easy attachment around the Adult Optokinetic Drum (DAL300). Item #: OKNADP1
  • Adult Acuity Slide
    Projector Slide Replacements Adult Acutiy Projector Slide Letter Acuity, Number Acuity, and Tumbling "E" Test This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
  • This screening battery is designed to detet vision problems in the pre-school population. It includes a test for visual acuity, eye alignment, binocular funtcion, farsightedness, lazy eye (amblyopia), and more. Utilizing new test such as the school bus test, this screening test for a great number of problems in a short period of time. This screening battery of test was designed for use by school personnel of members of service clubs such as Lions or Kiwanis with minimal training. Many test are pass/fail
  • Spatial Mapping - VTE
    Tumbling E Pad (Pad of 100) Printed with large 20/200 E on one side and a series of five 20/20 tumbling Es on the other- calibrated to a 20ft. distance. May be used to test and train peripheral awareness.
  • Basic Vertical Cards
    Basic Vertical Dr. Only Starter for any patient into fusion, anti-suppression and ranges of fusion. Set of 10 Cards For use with Bernell-O-Scope™ Item #: SMBV
  • Loose Risley Prism (Pair)
    Fits into the standard 38 mm eyewell of the Bernell-O-Scope or any standard trial lens frame. Each prism yields 20 PD for a total of 40PD. Now you can set any amount of BI, BO, or vertical prism into the stereoscope to do training procedures. May be used for distance training by removing the cardholder. Item #: ARPHH20
  • Bernell Red/Green Flipper
    Red/Green Flippers Quality, four-well flipper bar features two alternating sets of red and green lenses. Reverses Base-In/Base-Out demand with each flip. Item #: BC1270RG
  • ColorDx Pediatric 15
    Same great test, but in a new and improved package! The ColorDx Pediatric 15 is the newest version of Color Vision Testing Made Easy or CVTME. As the Gold Standard pediatric assessment of color deficiencies or color blindness See The Multi-Ethnic Pediatric Eye Disease Study published by the AAO, CVTME™ is used in over 40 countries and has been validated for illiterates at the US Special Olympics. Featuring the proven Waggoner six confusion-color strategy, the pediatric test is used in a broad range of settings: pediatrics, eye physicians, school nurses, and many other disciplines of health care, in any language, world-wide. This easy to administer test features both hidden and non-hidden shapes that allow for positive reinforcement even while testing color deficient children by allowing successful answers on most targets. This success-reinforced strategy is also useful for assessment of malingering. Designed by color vision expert Dr. Terrace Waggoner, this new edition features enhanced digital colorimetery production methods, durable page and binding materials, and magnetic light-protective storage case and enhanced digital colorimetery production method and durable page materials and binding. Brilliantly simple to take, easy to score and just plain fun for children.
  • Tumbling E Pad
    Tumbling E Pad (Pad of 100) Printed with large 20/200 E on one side and a series of five 20/20 tumbling Es on the other- calibrated to a 20ft. distance. May be used to test and train peripheral awareness.
  • Tranaglyph Variable Kit (925 Series) without BC51
    Variable Tranaglyph™ Kit (925 Series) Similar to the 920 Trainer, the 925 has an added vertical scale. Variable sliding trainer has a horizontal range of 36D, Base-In/Base-Out, and +/- 5D range at vertical.
  • Vectogram Mother Goose
    8-1/4" x 5-1/2" Polarized vectograms ensure testing and training at actual distances. Vectograms stabalize fusion and steropsis., eliminate suppression and develop simultaneous vision. Used in monocular, binocular, pursuit and saccadic training, vectograms help correct and prevent anomalies involving projection and hand-eye coordination. Ideal for use with Bernell's Dual Polachrome™ Trainer
  • Vergence FacilityVergence Facility 12D BO and 3D BI
    A good binocular screening device. Performed at a distance of 40 cm with a target of 20/30. Most normal patients can cycle between these prims 15/minute. Those with difficulty should be more thoroughly tested. 12D Base-Out and 3D Base-In. Prism is 1.5 inches square. Item #: G1110+
  • Bernell Necklace 3D Variable Tranaglyph 1Bernell Necklace 3D Variable Tranaglyph
    New 3D Modeled Variable Tranaglyph. Comparable to the popular Quoit Vectogram.
  • Variable Tranaglyph AVariable Tranaglyph
    Variable Tranaglyph™ Kit (500 Series) Variable prismatic red/green slides help build initial fusional reserves through peripheral and central fusion as well as stereopsis. Effective home training slides feature 5.5" x 10.5" red/green targets on transparent vinyl. Item #: BC500+
  • Frisby Stereo Test
    All Frisby Stereo Test Present "real depth" objects viewed with natural vision: not testing glasses are required. Each plate has four random-patten squares, with a circle of pattern elements, lying in depth relative to its surround. The depth effect is due to the circle and its surround being printed on opposite sides of the plate. The purpose of the Frisby Screening Stereo Test - Single Plate, is to demonstrate the presence of stereopsis.