Bernell

//Bernell
  • ColorDx Waggoner Standard 24 Plate Edition
    Same great test as before, but with a new and improved package! One of only two color vision tests validated and required for Naval Aviators. ColorDx is new brand identity for the proven Waggoner six confusion-color strategy used by physicians, Ophthalmologists, Optometrists, and nurses worldwide. This military grade test is used by the US Army and for FAA annual flight physicals requiring color vision testing and has been independently validated by both academic institutions and military services. This new edition features enhanced digital colorimetery production methods, durable page and binding materials, and magnetic light-protective storage case. The ColorDx Standard 24 is designed and licensed from color vision expert Dr. Terrace Waggoner and is the newest edition of the Waggoner PIP-24 (PIPIC 24).
  • ColorDx Pediatric 15
    Same great test, but in a new and improved package! The ColorDx Pediatric 15 is the newest version of Color Vision Testing Made Easy or CVTME. As the Gold Standard pediatric assessment of color deficiencies or color blindness See The Multi-Ethnic Pediatric Eye Disease Study published by the AAO, CVTME™ is used in over 40 countries and has been validated for illiterates at the US Special Olympics. Featuring the proven Waggoner six confusion-color strategy, the pediatric test is used in a broad range of settings: pediatrics, eye physicians, school nurses, and many other disciplines of health care, in any language, world-wide. This easy to administer test features both hidden and non-hidden shapes that allow for positive reinforcement even while testing color deficient children by allowing successful answers on most targets. This success-reinforced strategy is also useful for assessment of malingering. Designed by color vision expert Dr. Terrace Waggoner, this new edition features enhanced digital colorimetery production methods, durable page and binding materials, and magnetic light-protective storage case and enhanced digital colorimetery production method and durable page materials and binding. Brilliantly simple to take, easy to score and just plain fun for children.
  • Clown Vectogram
    Variable Vectogram Clown Vectogram 8-1/4" x 5-1/2" Polarized vectograms ensure testing and training at actual distances. Vectograms stabilize fusion and steropsis, eliminate suppression and develop simultaneous vision. Used in monocular, binocular pursuit and saccadic training, vectograms help correct and prevent anomalies involving projection and hand-eye coordination. Ideal for use with Bernell's Dual Polachrome™ Trainer
  • Clock 3D Variable Randot Tranaglyph 1Clock 3D Variable Randot Tranaglyph 1
    The new Random Dot 3D Clock Variable Tranaglyph is an excellent new training device for both the mid-level and final stages of base-in and base-out therapy. Unlike the typical 3D training images, random dot images can not be seen unless the highest level of fusion is achieved. The images simply look like a page full of dots, until the two eyes and brain combine these two sets of unique images into a single three dimensional image. This makes it an excellent therapy technique for those patients who are simply guessing or malingering with traditional cards sets. The level of fusion needed is the most difficult to obtain and requires the highest level of visual processing, which makes it an excellent finalization exercise. For patients who have had limited binocular vision, such as the recently corrected amblyopic or strabismic patient, this task may prove to be too difficult. For those patients, you may need to start with a 500 series tranaglyph, then progress to the 600 series and finalize with the Random dot series. Item #: BC12+
  • Children Yoked Prism Set
    Yoked Empty Rotating Prisms (VTE) Plastic frame with nasal anatomical fit for children. Blue and Red Colors Item #: E/FRRYPC
  • Child Vectographic Slide
    Child Vectorgraphic Projector Slide → Training Demonstration → Tumbling E Monocular 20/100 – 20/15 (9 Lines) → Acuity Balance 20/30 – 20/20 (3 Lines) → Tumbling E Binocular 20/30 – 20/15 (4 Lines) → Fixation Disparity with Fusion Lock → Stereopsis 215 - 40 seconds of arc
  • Child Acuity Projector Slide
    Projector Slide Replacements Child Acuity Projector Slide Allen Figures, Tumbling "E", Landolt "C" This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
  • Cardiff Acuity Test Set
    Cardiff Acuity Test Set™ with 36 cards and occluding glasses An upgrade for the Cardiff Acuity Test™ is now offered to meet the differing needs of Pediatric vs. Low Vision patients (Item #: NCATSLVU). The Low Vision upgrade kit includes a set of 3 cards each of levels A, LVB and LVA plus three red dividers. The standard set covers 12 acuity levels from 20/160 to 20/12.5. This version also include a pair of 4608R Butterfly foamy occluding glasses. The Low Vision set covers 14 levels from 20/320 to 20/12.5. There are three cards at each of these acuity levels. Intended for test distances of 1 meter and 50 cm. Cards are laminated and measure 7 3/4 by 10 1/2 in (20 by 27 cm) and are labeled by acuity level equivalents in decimal, meters, feet, Snellen and LogMAR for both test distances.
  • Butterfly Acuity Test with Lea Symbols
    Butterfly Acuity Test with Lea SYMBOLS® Test designed to rapidly test for amblyopia & strabismus using gross thru fine stereopsis (4800 to 20 sec of arc) - Graded Circle Test from 800 sec now down to 20 sec - No monocular clues - New improved booklets - Answer Key on back cover - Includes polarized viewers
  • Black Background TranaglypBlack Background Tranaglyp
    Black Background Tranaglyphs™ These offer excellent cancellation with no ghost images. These fixed demand targets provide flat fusion from 1-3 prism diopters, 2nd & 3rd degree fusion from 4-28 PD. BI & BO therapy is possible using a R/G flipper or switching the lenses in the goggles. (Set of 5 cards and one R/G Flipper) Size: 10.5" x 5.5"
  • Black Background TranaglyphBlack Background Tranaglyph
    These offer excellent cancellation with no ghost images. These fixed demand targets provide flat fusion from 1-3 prism diopters, 2nd & 3rd degree fusion from 4-28 PD. BI & BO therapy is possible using a R/G flipper or switching the lenses in the goggles. (Set of 5 cards and one R/G Flipper)
  • Binocular Accommodative Saccadic SeriesBinocular Accommodative Saccadic Series
    The BASS-PL series is a highly sensitive measure of the relationship between Binocular alignment (fixation disparity) and Accommodative function (clarity) during a Series (stamina) of cognitively loaded Saccadic eye movement. This series is designed to be a more dynamic measure of binocular/accommodative function during a saccadic eye movement task by involving a sequence of saccadic indentification targets at two acuity levels; 20/100 & 20/63. Complete system includes: therapy binder and pen, pair of polarized viewers, instruction manual, set of 20/100 target and vectographs and a set of 20/63 target and vectographs. Item #: BASSPL+