- Optimized for Anterior Segment Viewing
- IOL-Friendly Photodisruption
- Better Performance Over the Long-Term
- Faster Treatment
- Pinpoint Precision
- Accurately Position Optical Breakdown
- Designed to Maximize Your Workflow
- Greater Efficiency at the Touch of a Button
- A Wider View
- Configured to Meet Your Needs
-
Eye Cubed™ features real time imaging, advanced movie mode, real-time image enhancement, and a range of self-calibrating "best fit" probes. -
The restorative surgical option for glaucoma
Canaloplasty is a highly effective surgical treatment for moderate to later stage open-angle glaucoma. Performed using Ellex's iTrack™ surgical system, it's a minimally invasive, efficacious and safe technique that restores the eye’s natural outflow system function to reduce elevated intraocular pressure (IOP). -
Tango™ combines a full-featured SLT laser with a powerful, precise YAG laser, helping you to better manage both OAG and ACG patients, while also providing a highly effective solution for capsulotomy procedures. Engineered and built by Ellex, Tango™ brings together 30 years of manufacturing expertise and cutting-edge technology to deliver consistently better treatment results. Featuring a proprietary, patented dual-mode laser cavity, which allows you to instantly – and reliably – switch between SLT and YAG modes, combined with a custom-designed power supply that maintains optimum system stability for greater shot-to-shot consistency, Tango™ allows you to perform SLT and YAG treatments with improved accuracy and greater efficacy over the long-term.
Product Information
-
The new Ultra Q Reflex™ is the only YAG laser designed to perform both anterior and posterior YAG treatments – and is ideally suited for the treatment of vitreous strands and opacities. 1. Capsulotomy with New Generation IOLs 2. Laser Vitreolysis for the Treatment of Floaters 3. Peripheral Iridotomy for Glaucoma
Product Information
1. Optimized Optics for Better Viewing 2. Reflex Technology 3. IOL-Friendly Photodisruption 4. Better Performance Over the Long-Term 5. Pinpoint Precision 6. Accurately Position Optical Breakdown 7. Designed to Maximize Your Workflow 8. Faster Treatment -
Integre PRO's high-power yellow-red configuration delivers the full treatment spectrum of tradition three-color lasers in a slimline laser/ slit lamp design - re-defining multi-color laser technology.
Better Diagnosis and Treatment All-In-One
The all-in-one laser/slit lamp design of Integre Pro™ features a purpose-built slit lamp optimized for use in the posterior segment. Not only does this provide better depth perception, but it also offers optimum illumination of the fundus and a wider peripheral view. Additionally, Integre Pro’s treatment laser delivers a uniform energy distribution across the full diameter of the spot, from the beginning to the end of exposure – ensuring consistently better performance in the treatment of retinal disease.Clinical Versatility
Integre Pro™ can be configured with up to two wavelengths in order to best meet your clinical requirements. Choose from a combination of 561nm yellow, 670 nm red or 532nm green, including: 1. yellow-red configuration (561 nm and 670 nm) 2. green-red configuration (532 nm and 670 nm) 3. green configuration (532 nm) 4. yellow configuration (561 nm)Designed to Maximize Your Workflow
Unlike other photocoagulator systems, which require an external dichroic or fixed mirror in order to connect the laser to the slit lamp, Integre Pro’s unique, integrated laser/slit lamp design channels the laser directly through the slit lamp optics. The end result is better visualization and optimal illumination. In addition, this integrated design minimizes system downtime, because there are no exposed fiber optic or electrical cables. -
Integre PRO Scan combines multi-color photocoagulation with precise computer-controlled pattern scanning in our unique all-in-one laser/slit lamp design.
A Pattern and Wavelength for Every Pathology
Whether accurately positioning focal treatment in the macular area, or performing PRP in the periphery, Integre Pro Scan™ provides a pattern and wavelength for every pathology. The system offers a comprehensive array of pattern combinations: shape, size, and rotation can be fully customized in order to best meet your clinical requirements. Patterns of up to 16 spots can be delivered sequentially, as well as single spots. In addition, the system’s computer-controlled operation ensures precise pattern spacing and consistent shaping of laser spots and patterns for more accurate, consistent treatment results. Integre Pro Scan™ also provides a number of wavelength configurations, including two dual-wavelength configurations. This includes a high-power yellow and red configuration that delivers the full treatment spectrum of a traditional three-color multi-color photocoagulator.- yellow-red configuration (561 nm and 670 nm)
- green-red configuration (532 nm and 670 nm)
- green configuration (532 nm)
- yellow configuration (561 nm)
Predictable Treatment Outcomes
A proprietary ZenTec™ laser cavity delivers uniform energy distribution across the full diameter of the spot, eliminating hotspots and achieving optimal homogenous burns – delivering consistent, predictable treatment outcomes over a number of different operating conditions.Designed to Maximize Your Workflow
Unlike other photocoagulator systems, which require an external dichroic or fixed mirror in order to connect the laser to the slit lamp, Integre Pro Scan’s unique, all-ine-one laser/slit lamp design channels the laser directly through the slit lamp optics. The end result is better visualization and optimal illumination. In addition, this integrated design minimizes system downtime, because there are no exposed fiber optic or electrical cables. -
Solo™ is engineered to be faster and more precise. The system’s proprietary cavity facilitates effective heat transfer and cooling to deliver the industry’s fastest SLT firing rate at 3 shots per second. In addition, an automatic calibration process and a series of test-fire sequences uses feedback from the system’s energy monitor in order to constantly adjust system output, enabling precise adjustment of parameter settings at 0.1 mJ increments.
-
Considered to be the industry’s leading microsurgical YAG laser, Ultra Q™ features a patented, proprietary cavity and a custom power supply, which allow you to perform capsulotomy and iridotomy procedures at lower, more efficient power levels and with greater shot-to-shot consistency. It is also the world’s fastest YAG laser, with a firing rate of 3 shots per second.
IOL-Friendly Photodisruption
Ultra Q™ achieves the industry’s lowest energy optical breakdown at 1.8mJ (in air) to cut tissue more efficiently with fewer shots and less cumulative energy. Featuring an Ultra Gaussian beam profile, Ultra Q™ focuses more energy into the center of the beam profile to deliver greater energy density. Not only does this reduce the amount of energy needed to effectively perform capsulotomy and iridotomy treatments, it also greatly reduces the risk of lens pitting.Capsulotomy for Presbyopic IOLs
A precise capsulotomy is essential for IOLs that correct presbyopia through implantation in the posterior chamber’s capsular bag. Good IOL centration, in terms of the pupil, optimizes lens performance. In contrast, decentration can cause halos and poor vision. The goal is a perfectly centered, precise capsulotomy that will not affect the tension of the bag and the position of the IOL in the visual axis. The precision and ultra-low energy optical breakdown provided by Ultra Q™ creates a capsulotomy opening that is precisely controlled, without causing damage to the lens – even if the lack of a ridge makes the capsule adhere to the optic.Iridotomy for Phakic IOLs
Refractive IOLs that are designed to correct myopia, or hyperopia (also known as Phakic IOLs) can be placed in front of the iris or between the iris and the natural lens. To prevent any possibility of IOL-induced pupillary block, these lenses require peripheral iridotomies prior to surgery. The iridotomy aperture must be large enough to ensure a balanced aqueous flow, yet small enough so that no light is transmitted back to the pupil, which can cause double vision. Ultra Q™ enables you to create a precise size of the iridotomy, often in a single shot that uses lower energy than other YAG lasers.Selective Capsulotomy
Selective Capsulotomy performed with Ultra Q™ can effectively address ACCS and PCCS associated with the implantation of accommodative IOLs – allowing refinement of refractive outcomes following IOL surgery. -
Versatility, quality
Patients present a diverse range of eye conditions for you to evaluate and threat. With Tango Reflex™ from Ellex, you can expand the scope of care you’re able to provide, and all at the absolutely highest standard of safety and efficacy. -
The intuitive diagnostic ultrasound platform
If you’re searching for an easily reconfigurable ultrasound platform that covers all examination and measurement scan modes in an easy-to-use, compact design, Eye One™ is the solution you're looking for. From diagnostic A-Scan to high-frequency B-Scan, Eye One™ delivers comprehensive capability to meet your ultrasound needs for both the posterior and anterior segments.
-
Minimally invasive, maximally effective
Behind the apparent simplicity of ABiC™ and Canaloplasty is the iTrack™ surgical system. Intelligently designed and meticulously tested across each treatment step, the iTrack™ surgical system comprises the iTrack™ microcatheter, the ViscoInjector™ viscoelastic injector, and the iLumin™ illumination source. -
The optimum in minimally invasive, canal-based glaucoma surgery
With a mild touch and manifest efficacy, ABiC™ performed with the iTrack™ surgical system is a comprehensive minimally invasive glaucoma surgery that can effectively reduce IOP and eliminate or reduce the medication burden. Restorative and atraumatic, ABiC™ can be performed across the entire glaucoma disease process – and in conjunction with other treatments and MIGS options.