-
Illiterate Tumbling E ETDRS vision chart with proportionally spaced (geometric progression) lines; line sizes range from 20/200 to 20/10 (6/60 to 6/3) equivalent.
-
The Sheridan-Gardiner Test contains both near vision and distance vision tests according to the Faculty of Ophthalmologists and Snellen Standards. This Test also includes a reduced Snellen Test. Testing depends on matching shapes rather than identifying or naming letters. All are reversible. The Sheridan Gardiner Test is primarily designed for children but is also usable for deaf mute or other patients unable to interact with traditional letter based visual acuity tests. Results are more reliable than illiterate E or similar tests. A series of orthoptic booklets in washable plastic finish are included with the basic kit to augment the range of letters in each size.
-
Pocket size cards for testing and evaluating non-readers. Seven different test targets printed on either side of 4 plastic cards with instructions on eigth side. Washable. Handy test for student clinicians and practicing professionals alike.
-
This screening battery is designed to detet vision problems in the pre-school population. It includes a test for visual acuity, eye alignment, binocular funtcion, farsightedness, lazy eye (amblyopia), and more. Utilizing new test such as the school bus test, this screening test for a great number of problems in a short period of time. This screening battery of test was designed for use by school personnel of members of service clubs such as Lions or Kiwanis with minimal training. Many test are pass/fail
-
Vectographic Projector Slide Pediatric Slide This pediatric projector slide test depth perception and binocularity under distance conditions. The top portion of each slide is a standard non-vectographic projector slide. The bottom portion is a vetographic slide that contains suppression control targets, a distance stereo acuity test, fixation disparity and binocular balance. Slide fits most AO and Marco projectors, and there are adaptable to a 10' or 20' lane. REQUIRES POLARIZING SCREEN.
-
The OCULUS Binoptometer® 4P is a professional screening instrument for testing all relevant visual functions. The used future-oriented technology allows an almost unlimited representation of various vision tests. Vision-screening instrument with contrast sensitivity testing and optional mesopic vision and glare sensitivity testing.
New Test Presentation
Vision tests are presented on a high-resolution micro-color display, allowing a virtually unlimited presentation of vision tests.Unbeatable
Contrast sensitivity, optional mesopic vision and glare sensitivity testing with just one instrument.Ergonomic
Convenient height adjustment range of 4.13 inch (10.5 cm). In addition, the viewing angle is fully adjustable up to a 35° downgaze, thus enabling testing to be done ergonomically with any eyeglasses. -
Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → LEA Symbols® 20/100 – 20/10 (18 Lines) → LEA Numbers® (16 Lines) (Multiple Lines 20/50 – 20/10) → Sloan Numbers 20/100 – 20/10 (16 Lines) (Multiple Lines 20/50 – 20/10) Item #: VA3202
-
Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → LEA Symbols® 20/100 – 20/10 (18 Lines) → LEA Numbers® (16 Lines) (Multiple Lines 20/50 – 20/10) → Sloan Numbers 20/100 – 20/10 (16 Lines) (Multiple Lines 20/50 – 20/10) Item #: VA3203
-
The Single Symbol Book is ideal for people who cannot perform when tested with a line test. This book can help determine the best resolution of the visual pathway in a child/adult with amblyopia or impaired vision. Single optotype line sizes from 20/200 to 20/8 (6/60 to 6/2.4) equivalent.
-
Pediatric near vision card featuring LEA Symbols pediatric symbols for testing children or illiterate adults at 16" (40 cm). It's small size makes it easy to carry or store. Front side contains proportionally-spaced lines in logarithmic progression with line sizes ranging from 20/400 to 20/10 (6/120 to 6/3) equivalent. The reverse side features pediatric symbols in 50% spaced rectangle (Massachusetts Visual Acuity Test format). Line sizes range from from 20/100 to 20/16 (6/30 to 6/4.8).
-
This test assesses a child's functional vision at near distances. Can also be used to familiarize child with testing procedure before introducing a distance test. Proportionally spaced (logMAR) lines on one side and more tightly- spaced symbols on the opposite side. Line sizes range from 20/400 to 20/10 (6/120 to 6/3) equivalent, 0.05 to 2.00. Response key printed on test card. Includes training cards and instructions. Card measures 8" x 10" (20.3 cm x 25.4 cm).
-
Handheld vision test with LEA Symbols pediatric symbols features 50% spaced contour interaction bars to provide single optotype acuity with the proper crowding effect. Optotype line sizes from 20/100 to 20/20 (6/30 to 6/6) equivalent. This book can also be used for vision testing of illiterate adults or geriatric patients. Includes response key, flash cards, and instructions. 17 pages. 4" x 4" (10.2 cm x 10.2 cm).