Universal trial frame holds 3 lenses in front and 1 behind the frame. PD Range: 24mm to 40mm on each side. Adjustments: Temple length/angle, nosebridge height/angle, 360 -
Handheld vision test with LEA Symbols pediatric symbols features 50% spaced contour interaction bars to provide single optotype acuity with the proper crowding effect. Optotype line sizes from 20/100 to 20/20 (6/30 to 6/6) equivalent. This book can also be used for vision testing of illiterate adults or geriatric patients. Includes response key, flash cards, and instructions. 17 pages. 4" x 4" (10.2 cm x 10.2 cm). -

Near and Far Chart Set provides letter and number matrix for testing and accommodative vision training. This is a new take on the classic Hart Chart used by professionals for years. The Red/Green allow or anti-suppression training, in addition to accommodative training. -

The Welch Allyn RETeval-DR Electroretinograph is designed for healthcare providers who want to improve management of their patients with diabetes. In just three minutes, you can objectively screen for vision-threatening diabetic retinopathy (VTDR) wherever patients receive care. Welch Allyn RETeval-DR Electroretinograph enables efficient, comfortable, non-mydriatic screening for VTDR that improves patient compliance to help preserve vision in your patients with diabetes. NOT AVAILABLE IN THE U.S.A. -

PART #V20LC Perhaps the most recognized lens around the world, the Volk 20D is the lens that started the legacy of double aspheric lens design for BIO and is still considered as a gold standard. The contributing factors for this are the perfect balance of field of view and magnification of the 20D. The working distance of 50 mm also makes lens manipulation a comfortable experience for the examiner. This lens is perfect for general diagnosis of patients with a 3x magnification and field of view that allows visualization up to the mid peripheral region. The dynamic examination with the appropriate eye movements by the patients allows viewing of the peripheral retina as well as detailed examination by BIO in the primary position provides a comprehensive estimate of retinal health. Thus, this lens is a great choice both as a first line of diagnosis as well as a high level central retinal examination. -

iCare EIDON widefield TrueColor Confocal fundus imaging system
Key features- Multiple imaging modalities including TrueColor, blue, red and Red-Free and infrared confocal images
- Widefield, ultra-high-resolution imaging
- Capability to image through cataract and media opacities
- Dilation-free operation (minimum pupil 2.5 mm)
- Flexibility of fully automated and fully manual mode
- All-in-one compact design, no additional PC required
-

First introduced in 1999, the OCULUS Pentacam® is commercially available since 2003. It is the first automatically rotating Scheimpflug camera. During the rotating scan that takes max. 2 seconds, up to 50 Scheimpflug images of the anterior eye segment are captured. The examination is released automatically and is user independent. During the scanning process, the patient’s eye motions are captured using a second camera and compensated mathematically. Ray tracing is used to compensate for optical distortions. This combination is the basis for calculating solid data for further evaluation. More than 100 published studies and papers prove the efficiency of this concept. The OCULUS Pentacam® measures the cornea from limbus to limbus. It supplies topographic data on elevation and curvature of the entire anterior and posterior corneal surface. The corneal thickness (pachymetry) is measured and presented graphically over its entire surface. A topography based keratoconus detection and quantification are performed. The anterior chamber depth, chamber volume (size) and the chamber angles are calculated and presented for the Glaucoma screening. The illumination of the eye using blue LED light makes corneal and lens opacities (cataract) visible. For patients information, the anterior chamber can be visualized and displayed with the virtual tomography model. After the examination, OCULUS Pentacam® provides an indice report that summarizes the abnormalities found during the scan. This report is based on clinical published studies and articles that define abnormalities. The OCULUS Pentacam® can be customized with two software packages and several software modules to fit your exact needs. -
Plano Stick Prism Item #: ASPSPL -
Set Includes Vertical prism bar with the following powers: 0.5,1,1.5,2,3,4,5,6,8 & 10 Horizontal prism bar with the following powers: 1,2,4,6,8,10,12,15,20 & 25 Item #: ACPS20 -

Flat prisms or Corrected Curved Prisms Professional training with two yoked prism pairs. Beginning with the highest powers through which a patient can fuse and focus, prism flippers are exchanged for the next higher powers through the training sequence. Great for early presbyopes with high exo with new bifocals! Please specify diopter power when ordering and if flat prism or corrected for abberations and made as thin as possible (corrected curved). Available in sizes 1D - 10D Item #: BC1275+ -
Anthony 15 Hue-Test Desaturated Test revels color blindness by using light hues. Diagnoses abnormal congentia, trichromats, and dyschromatopsia. -
This test for illiterate patients has HOTV letters on one side and Allan figures on the other. Can be used with HOTV near card for matching with non-verbal patients. 21.5" x 11.5"