PART #V60C The 60D lens is one of the high magnification fundoscopy lenses used for a thorough and detailed examination of the central retina such as the macula and the nerve head. The trademark double aspheric design provides excellent detail and imaging for detecting subtle details and indications of retinal abnormalities. The optical profile of this lens requires a longer working distance of 18 mm from the patient. The high magnification provided by this lens is a great choice for diagnosis and assessment of the severity of Age-Related Macular Degeneration, following cup to disk ratios in patients and capillary hemorrhages. Dilation is required to obtain optimum retinal imaging with the 60D.
-
Optomed Smartscope® PRO is the next generation hand-held medical camera that provides high image quality which fulfills international ISO 10940 fundus camera standard requirements. Interchangeable modular optics make the camera even more versatile. The lightweight camera incorporates advanced technology in a portable design. Smartscope PRO camera provides accurate and silent autofocus which makes image capturing quick and easy. The camera is also equipped with Wi-Fi for advanced image transfer to any PC or mobile device. The Smartscope PRO comes with Patient Data Management software (sold separately) with full DICOM and PACS compliance to ensure seamless interoperability with hospital networks and practice management systems.
-
Solo™ is engineered to be faster and more precise. The system’s proprietary cavity facilitates effective heat transfer and cooling to deliver the industry’s fastest SLT firing rate at 3 shots per second. In addition, an automatic calibration process and a series of test-fire sequences uses feedback from the system’s energy monitor in order to constantly adjust system output, enabling precise adjustment of parameter settings at 0.1 mJ increments.
-
The Lang Fixation Cubes have been designed by J. Lang for the assessment of eye fixation, motility, accommodation, convergence, for cover test, and to prepare the child for testing with the Lang-Stereotest® or the Lang-Stereopad®.
5 child-friendly objects are presented on the side and the top of the cube. Some of them are also included in the two versions of the Lang-Stereotest® and of the Lang-Stereopad®, and on the Lang Fixation stick.
The Cube has a white handle.
Each turn of the cube shows a new object. The star on the top side and the other objects can also be used for the test of convergence.
-
Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → LEA Symbols® 20/100 – 20/10 (18 Lines) → LEA Numbers® (16 Lines) (Multiple Lines 20/50 – 20/10) → Sloan Numbers 20/100 – 20/10 (16 Lines) (Multiple Lines 20/50 – 20/10) Item #: VA3203
-
9" x 14" TRANSLUCENT PLASTIC MAY BE USED WITH ILLUMINATED TEST CABINET OR AS A WALL CHART 20/200 to 20/15. Item #: BC1262
-
ARMD Test Pad Amsler grid pad for testing and monitoring macular problems. Ideal for patients to take home. Heavy, non-wrinkle paper Pad of 50 sheets
-
Projector Slide Replacements Family Practice Slide Letter Acuity, Astigmatic Clock, Tumbling "E", Allen Figures This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
-
The Sheridan-Gardiner Test contains both near vision and distance vision tests according to the Faculty of Ophthalmologists and Snellen Standards. This Test also includes a reduced Snellen Test. Testing depends on matching shapes rather than identifying or naming letters. All are reversible. The Sheridan Gardiner Test is primarily designed for children but is also usable for deaf mute or other patients unable to interact with traditional letter based visual acuity tests. Results are more reliable than illiterate E or similar tests. A series of orthoptic booklets in washable plastic finish are included with the basic kit to augment the range of letters in each size.
-
Non-Variable Vertical Tranaglyph™ Slide (70 Series) The test for vertical fusional reserve. Non-variable prismatic red/green slides provide 0.25PD to 3.0PD in 0.25PD increments. Allows for normal head tilt without eye strain or double vision. Red/green targets are silk screened on frosted vinyl. Slides measure 5.5" x 10.5". Can be used with Polachrome Trainer.
-
The restorative surgical option for glaucoma
Canaloplasty is a highly effective surgical treatment for moderate to later stage open-angle glaucoma. Performed using Ellex's iTrack™ surgical system, it's a minimally invasive, efficacious and safe technique that restores the eye’s natural outflow system function to reduce elevated intraocular pressure (IOP). -
BINOCULAR ACCOMMODATION AUTO REF/KERATOMETER WAM-5500 is a unique Refraction-Keratometer that allows the patient to keep natural binocular vision duringmeasurement. This binocular vision helps the patient to eliminate possible instrument accommodation and provides accurate refraction examination. WAM 5500 is also equipped with the function that enables the measurement of far and near distances refractive power as well as the measurement of pupil diameter simultaneously.