-
Morgenstern Color Fusion Cards - Convergence B DR ONLY USED WITH BERNELL-O-SCOPE™ BUILD LARGER RANGES OF VERGENCE. WORK IN AND OUT OF INSTRUMENT. GOOD FOR "TROMBONING" IN STEROSCOPE AS WELL AS "POINTING". SET OF 10 CARDS Item #: SMCB
-
Flat prisms or Corrected Curved Prisms Professional training with two yoked prism pairs. Beginning with the highest powers through which a patient can fuse and focus, prism flippers are exchanged for the next higher powers through the training sequence. Great for early presbyopes with high exo with new bifocals! Please specify diopter power when ordering and if flat prism or corrected for abberations and made as thin as possible (corrected curved). Available in sizes 1D - 10D Item #: BC1275+
-
Six-piece set includes: 2D,3D,4D,5D,6D and 8D flippers. Professional training with two prism pairs. Beginning with the highest powers through which a patient can fuse and focus, prism flippers are exchanged for next higher powers through the training sequence. GREAT FOR BEGINNING PRESBYOPES WHO HAVE EXO WITH THEIR BIFOCALS! All flippers have corrected curve lenses and come in a deluxe black carrying case. Save money with this kit! Note: Prism diopter powers are listed per lens. For example, a 4PD flipper will have two 4PD lenses to make a 8PD range. So, 4PD flipper = 8PD range. Item #: BC1275SETCC
-
Our cutting edge retinal imaging technology is customized to fit the needs of your practice. The next generation of Optos technology, Daytona has been scaled to accommodate smaller office spaces while providing ultra-high resolution imaging, and adding ultra-widefield autofluorescence capabilities. Features:
- Non-mydriatic ultra-high resolution images in under a second, through 2 mm pupils and many cataracts
- Red and green lasers; each wavelength provides information for interpretation and diagnosis. Channels can be viewed separately:
- Green (532 nm) “red-free” visualizes the sensory retina to the RPE
- Red (635 nm) shows deeper structures of the retina (RPE to Choroid)
- Ultra-widefield autofluorescence imaging with green laser light displays lipofuscin in the RPE
- Images are available immediately and stored electronically for future comparison or telehealth applications
- Innovative software tools enhance image evaluation
- DICOM compatible
-
-
Deluxe Kit has (28) prisms, (6) frames, & Maddox Rod in a wooden case with pre-cut foam to keep prisms safe & clean. Note: Prism diopter powers are listed per lens. For example, a 4PD goggle will have two 4PD lenses to make a 8PD range. So, 4PD goggle = 8PD range. Item #: 1138KIT28+
-
PART #VDGTLCM The digital clear mag is designed specifically for high magnification and detailed examination of the macula and optic disc with a 3.89x magnification. This lens is an easy transition for those who are used to handling a 20D lens with a similar lens ring size and working distance but with an added advantage of high magnification. This lens is a great choice for detecting and monitoring the subtle changes in the optic disc morphology in patients with diabetic retinopathy, glaucoma and age related macular degeneration.
-
Look more modern while improving your accuracy and decreasing remakes with your PAL's. This digital pupilometer is easy to use. Requires 4 AA batteries (not included).
-
The Direct Digital Pupil Gauge is a simple and inexpensive way to measure both monocular and binocular distances between eyes. This is necessary for accurate fitting of various ophthalmic lenses, especially multi-focals. It works by simply aligning the vertical stripes over the center of each pupillary reflex.
-
DISTANCE ACUITY GUIDE FOR PROJECTOR SLIDES Target size guide from 7.5ft to 26ft in 0.5ft steps, ranges up to 30ft.
-
Morgenstern Color Fusion Cards - Divergence A USED WITH BERNELL-O-SCOPE™ DIVERGENCE A CARDS. TRADITIONAL VT FOR FUSION RANGES & JUMP DUCTIONS WITH COLORFUL TARGETS. INCREASE IN DEMAND AND RANGE OF FLEXIBILITY. Item #: SMDA
-
Morgenstern Color Fusion Cards - Divergence B Used with Bernell-O-Scope™ Builds large ranges of vergence (pull all the way in and out). Work in and out of instrument. Hold in space and fuse, diverge, move fused targets and also converge some. Made for "tromboning" work in the stereoscope as well as "pointing". Each card features eclectic designs and unique arrangements. Item #: SMDB
-
The approved, design-award winning magnifying Loupe from OCULUS for professional and free time use.
Magnifying Glasses – Tool and Helper for Work and Play
1.8x to 2.5x magnification become child’s play. Whether you are a dentist, goldsmith, watchmaker, philatelist or modeler: the OCULUS Easyloupe® is your tool and helper for precise viewing of even the smallest of details.Customized for You - The OCULUS Easyloupe® Fits
The OCULUS Easyloupe® can be adapted to your vision needs with ease.- The OCULUS Easyloupe® is available in two models
- 1.8x Magnification, working distance 370 mm, large working field diameter of 90 mm
- 2.5x Magnification, working distance 400 mm, large working field diameter of 80 mm
- Easy, individual adjustment of the pupil distance (50 - 75 mm)
- Frame temples with spring hinges available in two different lengths (95 mm and 105 mm)
- Flexible ear pieces for a more comfortable and secure fit
- The OCULUS Easyloupe® is available in two models
-
Free space fusion performed in a new, inexpensive way. Black target circles are printed on two 6" x 7" clear acetate cards. A unique, accurate method of developing increased fusional range without the need for costly lenses or filters.
-
The new clear fixation paddle is 12" x 12" made of clear polycarbonate. Uses targets with cling material which adheres and removes easily from the front or back of the paddles by adhesion forces.
-
-
Enhanced light ouptut makes refractions easier than ever, by producing one of the sharpest, brightest and cleanest streaks available on the market. Discover unparalleled performance in a compact design with convenient, user-friendly features.
-
Adult LEA NUMBERS® chart for ETDRS Illuminated light boxes. Fits all existing ETDRS cabinets including both the ESV3000 and ESC2000. LEA NUMBERS® ETDRS chart contains optotypes in proportionally spaced (logMAR) lines; lines range from 20/200 to 20/8 (6/60 to 6/2.4) equivalent, 0.10 to 2.50. Fits in ESV3000 ETDRS illuminated cabinet.
-
The ESC2000 Illuminator Cabinet provides a uniform retro-illuminated testing surface, ideal for clinical testing of high contrast and low contrast LogMAR tests, including ETDRS, Lea Symbols, Lea Numbers, Landolt C, etc. The cabinet utilizes a pure-white LED light source. (Stand not included. Can be purchased separately. Part # GL50004)
-
Extra Aperture Rule™ Cards Select either Bernstein Bears for pediatric use or Sports/Action targets. Techniques and target designs are developed for children and adult motivation.
-
The intuitive diagnostic ultrasound platform
If you’re searching for an easily reconfigurable ultrasound platform that covers all examination and measurement scan modes in an easy-to-use, compact design, Eye One™ is the solution you're looking for. From diagnostic A-Scan to high-frequency B-Scan, Eye One™ delivers comprehensive capability to meet your ultrasound needs for both the posterior and anterior segments.
-
Eye Cubed™ features real time imaging, advanced movie mode, real-time image enhancement, and a range of self-calibrating "best fit" probes.
Customized Configuration to Best Meet Your Needs
With customized configuration of A-Scan and B-Scan modes, Eye Cubed™ covers all of your diagnostic ultrasound needs for both the posterior and anterior segments. Pre-op or post-op, A-Scan or B-Scan, retina or anterior segment: whatever your focus, Eye Cubed™ shows you more, in more detail, than any other device of its kind.High Resolution Goes Ultra
Eye Cubed’s 40 MHz UBM mode allows you to view anterior structures such as the cornea, iris, ciliary body, crystalline and intraocular lens more clearly than ever before. Whether determining the sulcus-to-sulcus measurement for accurate ICL sizing or the angle for potential angle closure and possible YAG laser iridotomy, Eye Cubed’s 40M Hz UBM mode is the gold-standard in high-resolution ultrasound.Essential Technology for Your Practice
Even in an era of high-tech OCT scanning and digital imaging, ultrasound is the only means to obtain a crucial view of the posterior segment when there is a dense cataract or vitreous hemorrhage in the eye – making it one of the most fundamental diagnostic tools in ophthalmology. Detection of disorders like posterior vitreous detachment (PVD) in opaque ocular media is easily achieved with B-Scan ultrasound.Innovative Imaging
Since acquiring Sacramento-based ophthalmic ultrasound pioneers Innovative Imaging Inc. in 2006, Ellex has been working hard to provide ever-increasing value to our Eye Cubed customers – and to develop our ultrasound technology platform. With the support of personalized, clinical ultrasound applications training by expert ecographers, Eye Cubed™ offers a total solution for your practice – and for your patients.Ophthalmic Edge
Visit the comprehensive online diagnostic teaching tool created by Yale Fisher, MD, to access lectures, monographs and cases studies covering a range of diagnostic technologies, including ultrasound and OCT. -
The DR-300 ezRead™ from Carson Optical transforms your television into a visual aid! Place the ezRead™ directly on top of your reading material to display the magnified image in full color on your television screen! Connect to your television in seconds using the supplied video cable. Internal led illumination ensures that the image on the screen is bright and easy to read. The size of your television monitor determines the actual magnification of the item. The larger the monitor, the greater the ezRead™ magnifies! The ezRead™ is ideal for those with low vision or macular degeneration. Operates with three AAA batteries (not included) or supplied A/C power adaptor. Magnification Table: 7x on a 17″ monitor, 11.5x on a 27″ monitor, 13.5x on a 32″ monitor, 17x on a 40″ monitor & 19.5x on a 46″ monitor
-
Designed for use in manual Chart Projectors including products from: R.H. Burton, Marco, Reichart, Topcon, and Woodlyn. Includes test for: → Tumbling E 20/400 – 20/200 (3 Lines) → Sloan Letters 20/100 – 20/10 (11 Lines) → Astigmatic Clock → Sloan Letters 20/50 – 20/10 (6 Lines) → Tumbling E 20/50 – 20/15 (5 Lines) → Allen Acuity 20/100 – 20/40 (4 Lines) Item #: VA1193
-
Projector Slide Replacements Family Practice Slide Letter Acuity, Astigmatic Clock, Tumbling "E", Allen Figures This family of projector slides are designed for testing all ages. Made of high quality photographic film, sealed between two pieces of glass to ensure sharp optotypes to maintain the integrity of your exam. Each slide must be adjusted for use on different length testing lanes.
-
Gem Polarized Variable Vectographic with Fixation Disparity Target → Stereopsis depth of 700 seconds of arc → Includes Fixation Disparity target with central Fusion Lock → 16 diopter range for Base-In (Divergence) Training → 24 diopter range for Base-Out (Convergence) Training → Total accommodation range of 40 diopters → New improved Vecto Guides → Now includes Therapy Binder → Now includes doctor and patient instruction manuals → Now includes Patient Vision Therapy Record Form → Includes Standard Polarized Viewers Item #: VA1060PL
-
This handheld circular pupillometer device is used for measuring different size pupils. It was developed and researched by Dr. Jack Richman, O.D., as part of the Massachusetts Drug Evaluation and Classification Program (MDEP). This pupil measurement device is used by law enforcement officers across the country to assist in determining whether people are possibly impaired and/or under the influence of drugs. The reverse side has expected pupil size in different lighting conditions for non-impaired people. Item #: LV3553000
-
Farnsworth D15 Dichotomous Color Test Farnsworth Test for Congenital and Acquired color defects. The Farnsworth D-15 contains a reference disc holding notation 10 B 5 4 and fifteen numbered discs which make up an incomplete color circle. The patient arranges the discs and then evaluation of the patients arrangement separates 'normal' color perception from moderate and strong defects in deutan, protan or tritan axis color discrimination. The D-15 is housed in a plexiglass container. the disks are spread out on a table and arranged by the patient. The Farnsworth D-15 test is a subset of the well known Farnsworth 100 Hue Test. It is intended for classification instead of in-depth study of color vision defects. The D-15 and 100 hue tests are correlated. Growing Importance of Color deficiency Screening. In addition to congenital color deficiency screening there is growing evidence that adult acquired color deficiency, especially in yellow and blue perception, can indicate medical toxicity and other problems. Increasingly complex security and medical systems also require verification of all three types of color receptors. How the D-15 test works: The Farnsworth D15 is called 'dichotomous' because it is designed to separate subjects into one of two groups, 1) Strongly color deficient or 2) Mildly color deficient or color normal. This is accomplished by the arrangement of vivid (saturated) colored discs. A perfect score shows normal color perception. A non-perfect score is used to determine a medium or strong color deficiency.
-
Farnsworth Test for Congenital and Acquired color defects. The Farnsworth D-15 contains a reference disc holding notation 10 B 5 4 and fifteen numbered discs which make up an incomplete color circle. The patient arranges the discs and then evaluation of the patients arrangement separates 'normal' color perception from moderate and strong defects in deutan, protan or tritan axis color discrimination. The disks are spread out on a table and arranged by the patient. The Farnsworth D-15 test is a subset of the well known Farnsworth 100 Hue Test. It is intended for classification instead of in-depth study of color vision defects. The D-15 and 100 hue tests are correlated. Growing Importance of Color deficiency Screening: In addition to congenital color deficiency screening there is growing evidence that adult acquired color deficiency, especially in yellow and blue perception, can indicate medical toxicity and other problems. Increasingly complex security and medical systems also require verification of all three types of color receptors. How the D-15 test works: The Farnsworth D15 is called 'dichotomous' because it is designed to separate subjects into one of two groups, 1) Strongly color deficient or 2) Mildly color deficient or color normal. This is accomplished by the arrangement of vivid (saturated) colored discs. A perfect score shows normal color perception. A non-perfect score is used to determine a medium or strong color deficiency.
-
Variable slide adjust to determine fixation disparity or may be used with hand held prisms. Designed for phoroptor use. The card comes with a label which may be placed over the prism diopter scale for an additional scale in degrees. Reverse side of card includes reduced Snellen, fusional target and cross cylinder targets. 5-1/2" x 8" card and polarized goggle. Item #: BCFDC
-
Fixed Demands Tranaglyph™ Kit (60 Series) Ideal for testing or training in true space at the office or home. Eliminates suppression while developing fusion and stereopsis. Non-variable prismatic Red/Green slides build fusional convergence & divergence. 2PD increments from 0 to 30PD BI or BO. 10" x 5.5" Red/Green targets on frosted vinyl. Can be used with Polachrome Trainer. Item #: BC60K+
-
Fixed Demands Tranaglyph™ Kit (50 Series) Ideal for testing or training in true space at the office or home. Eliminates suppression while developing fusion and stereopsis. Non-variable prismatic Red/Green slides build fusional convergence & divergence. 2PD increments from 0 to 30PD BI or BO. 10" x 5.5" Red/Green targets on frosted vinyl. Can be used with Polachrome Trainer.Item #: BC50K+
-
Flippers are used to test and train for accomodative facility, accommadative rock, positive/negative relative accommodation and convergence and fusional convergence reserves. May delay bifocal use with some early presbyopes. Flippers assists in hyperopia screening and lens demonstrations. Help determine dominancy and powers when fitting monovision contacts. Durable white plastic holds shape under low heat for lens insertion. Powers listed on handle. Deluxe Black carrying case or the economy flipper holder included. Item #: BC1270SETSP
-
FLIPPER CASE INCLUDED. Professional level six piece set features plus/minus powers in 0.25, 0.50, 1.00, 1.50, 2.00 and 2.50 diopters. Deluxe black carrying case or the economy flipper holder included. Specify which you prefer. Flippers come with colored handle covers. Your account must be registered as a healthcare professional or a school/government in order to purchase this product.Item #: BC1270SET
-
Designed to rapidly test for amblyopia and strabismus using gross thru fine stereopsis (4800 to 20 seconds of arc). Graded circle test from 400 seconds now down to 20 seconds with no monocular clues. New improved booklet has answer key on back cover and includes polarized viewers.
- Graded circle test from 400 seconds now down to 20 seconds
- No monocular clues with NEW technology
- New improved booklet
- Answer key on back cover
- Includes both adult and pediatric polarized viewers
-
All Frisby Stereo Test Present "real depth" objects viewed with natural vision: not testing glasses are required. Each plate has four random-patten squares, with a circle of pattern elements, lying in depth relative to its surround. The depth effect is due to the circle and its surround being printed on opposite sides of the plate. The purpose of the Frisby Screening Stereo Test - Single Plate, is to demonstrate the presence of stereopsis.