- Easy Program of Refraction Sequences
- Control Box with Touch Panel for Easy Operation
- 5.7-inch color LCD
- Switching charts and LED
- Advanced dial with S/C/A mode keys
- Smart and smooth examinations
- Cross cylinder examination
- Built-In High Speed Line Printer with Automatic Paper Cutting
- Software Update with CompactFlash Card
- Ergonomically-Designed Refractor Head for Comfortable Examinations
- Compact design & wide visual field (40o)
- Smooth, quiet lens selection for faster examinations
- Power convergence and power PD
- R / L independent PD adjustment for improved precision
- Built-in clear and safe illumination (white LED)
- Easy-to clean: detachable forehead rest, face shields, and protective glasses with antifouling coating
- High quality near point card
- Eye Care Card System
- EMR (Electric Medical Record) Compatible
-
The New Auto Refractor RT-3100 Compact & Fast Examination
-
Key Features
- Patient-Friendly
- Smart, ergonimic design for patient comfort
- Wide visual field (40o)
- Easy Maintenance & Upgrades
- Quick & easy future upgrades with CompactFlash card
- User-Friendly
- Large color TFT LCD touch panel
- High speed line printer
- Forehead position detector (blue LED) for reliable measurement
- Patient-Friendly
-
- Minimum 0.9 m installation distance
- Combined with the Optometry System
- Night mode
- Operation with remote control
-
In contrast to conventional visual acuity systems, the SC-1600 displays the digitally stored chart images directly on the LCD screen
- Selectable Working Distance
- Wide Range of Image Dispkay
- Contrast Test
- Night Mode
- Indication of a Slide Image
- Black and White Inverse Function
- Smart Display Functions
-
- Simple and reliable refraction
- Triple-performance combination
- Flexible measurement style
- Easy installation
- Compact footprint
-
The OCULUS Binoptometer® 4P is a professional screening instrument for testing all relevant visual functions. The used future-oriented technology allows an almost unlimited representation of various vision tests. Vision-screening instrument with contrast sensitivity testing and optional mesopic vision and glare sensitivity testing.
New Test Presentation
Vision tests are presented on a high-resolution micro-color display, allowing a virtually unlimited presentation of vision tests.Unbeatable
Contrast sensitivity, optional mesopic vision and glare sensitivity testing with just one instrument.Ergonomic
Convenient height adjustment range of 4.13 inch (10.5 cm). In addition, the viewing angle is fully adjustable up to a 35° downgaze, thus enabling testing to be done ergonomically with any eyeglasses. -
With this product development, OCULUS is once again living up to its motto, "We focus on progress”. The OCULUS C-Quant makes it possible to measure the amount of straylight in a human eye individually and reliably. The effect of increased straylight in the human eye can be compared to looking through a dirty windshield.
-
Thanks to its ergonomic design, user-friendly program navigation and ease of operation, the OCULUS Centerfield® 2 Perimeter has proven itself to be an invaluable instrument in the Occupational Health area. The unit performs static perimetry up to 70° eccentricity. It also meets the requirements of the German Ophthalmological Society’s (DOG) Road Traffic Commission for conducting visual field testing in accordance with the regulations for the issuance of driver’s licenses and the Guidelines G25 and G41 issued by the German Institute for Occupational Health and Safety.
Ergonomic Design
The self-contained design and light-shielded viewer allow examinations to be conducted in normally lit rooms. Its robustness and light weight make the OCULUS Centerfield® 2 Perimeter the ideal unit for portable use, which is often a necessity in the Occupational Health area.Reliable Results
The results of the perimetric measurements are summarized in a clearly structured printout. Areas of abnormality can be quickly recognized and re-examination of these areas independent of the test point grid gives the diagnostic analysis even greater reliability.Modern Connectivity
The OCULUS Centerfield® 2 Perimeter can be operated via the USB port of a notebook or PC. Together with the supplied device software, this modern solution allows you to fully utilize all of the benefits of today’s IT systems, especially the network connectivity. This guarantees both safe storage of examination data and quick access to that data when needed. -
The revolutionary OCULUS Corvis® STL records the reaction of the cornea to a defined air pulse with a newly developed high-speed Scheimpflug-camera that takes over 4,300 images per second. IOP and corneal thickness can be measured with great precision on the basis of the Scheimpflug images.
Corneal Visualization Scheimpflug Technology
The revolutionary OCULUS Corvis® STL records the reaction of the cornea to a defined air pulse with a newly developed high-speed Scheimpflug-camera that takes over 4,300 images per second. IOP and corneal thickness can be measured with great precision on the basis of the Scheimpflug images.Measurement and Display Options
- IOP measurement
- Measurement of the corneal thickness
- Scheimpflug images of the 1st and 2nd applanation of the cornea
- Slow-motion video of the corneal deformation as a result of the air pulse
- Non-contact tonometer in combination with an ultra-high-speed camera for visualization of the deformation of the cornea in reaction to an air pulse (4,330 frames / sec.)
-
It ensures reliability when it comes to taking measurements, providing consultation and fitting contact lenses. The OCULUS Keratograph® accurate findings are something you can count on. The integrated keratometer and automatic measurement activation guarantee perfect reproducibility. In this way the OCULUS Keratograph® 4 also meets highest clinical standards for such procedures as tear film assessment and qualitative cornea analysis. It stands out by virtue of its versatility.
-
The OCULUS Keratograph® 5M is an advanced corneal topographer with a built-in real keratometer and a color camera optimized for external imaging. Unique features include examining the meibomian glands, non-invasive tear film break-up time and the tear meniscus height measurement and evaluating the lipid layer.
Gain Trust
With the OCULUS Keratograph® 5M, you can show your patients images they have never seen before. Gain patient trust by providing professional consultation during examinations and follow-ups.Easy-to-Understand Presentation
Actively integrate the OCULUS Keratograph® into your consultation. Many easy to understand displays support you in communication and patient education. Use your OCULUS Keratograph® 5M as a marketing tool to make your services transparent! -
First introduced in 1999, the OCULUS Pentacam® is commercially available since 2003. It is the first automatically rotating Scheimpflug camera. During the rotating scan that takes max. 2 seconds, up to 50 Scheimpflug images of the anterior eye segment are captured. The examination is released automatically and is user independent. During the scanning process, the patient’s eye motions are captured using a second camera and compensated mathematically. Ray tracing is used to compensate for optical distortions. This combination is the basis for calculating solid data for further evaluation. More than 100 published studies and papers prove the efficiency of this concept. The OCULUS Pentacam® measures the cornea from limbus to limbus. It supplies topographic data on elevation and curvature of the entire anterior and posterior corneal surface. The corneal thickness (pachymetry) is measured and presented graphically over its entire surface. A topography based keratoconus detection and quantification are performed. The anterior chamber depth, chamber volume (size) and the chamber angles are calculated and presented for the Glaucoma screening. The illumination of the eye using blue LED light makes corneal and lens opacities (cataract) visible. For patients information, the anterior chamber can be visualized and displayed with the virtual tomography model. After the examination, OCULUS Pentacam® provides an indice report that summarizes the abnormalities found during the scan. This report is based on clinical published studies and articles that define abnormalities. The OCULUS Pentacam® can be customized with two software packages and several software modules to fit your exact needs.
-
The next generation is here!
The new OCULUS Pentacam® AXL is a symbiosis of the time-tested OCULUS Pentacam® technology with completely new, high-precision measurement along the visual axis. Contact-free from the corneal surface to the retina. This compact device offers you a multitude of diverse measuring options:- Pentacam® measurements - The gold standard for measuring and analyzing the anterior segment of the eye - front and back surfaces of the cornea, total corneal refractive power (TCRP) and corneal thickness.
- Axial length measurements - The high-precision optical biometer precisely measures the axial length for the IOL power calculation.
- Combined measurements: OCULUS Pentacam® + Axial Length - Both measurements are captured in succession along the same axis, using the same alignment.
-
The OCULUS Pentacam® HR is a high-resolution rotating Scheimpflug camera system for anterior segment analysis. It provides crisp images of cornea, iris and crystalline lens. It measures the anterior and posterior corneal topography and elevation, total corneal refractive power, corneal power distribution, automatic chamber angle measurement in 360°, chamber depth and volume, HWTW, corneal and crystalline lens optical opacities. Standard Software: Belin/Ambrosio Enhanced Ecstasia, Holladay Report, Contact Lens Fitting, Cataract package and Refractive Package.
-
We now sell an optokinetic drum that has the same DC motor and control box as our Stand Rotator (BC1060). The OKN drum can rotate through a wide range of speeds but especially a wide range of very slow ratation and can reverse. See also the DAL300WR with a digital display of speeds. Unit is on wheels so that it can be more easily stored. Item #: DAL300W
-
The new OKN drum now has the same motor and control box as our stand rotator but is on wheels. This unit comes with the optional RPM display which accurately tells the speed of rotation. This would help in accurate testing of acuities on children or even in malingerers. Item #: DAL300WR
-
Features
- Providing a comprehensive solution for retina and glaucoma analysis
- Accurate image capture with a SLO-based eye tracer
- Selectable OCT sensitivity that allows acquisition of B-scan images through media opacities
- Tracing HD for accurate averaging of up to 120 image
- Glaucoma analysis with wide-area normative database 9 x 9 mm
- High resolution AngioScan OCT-Angiography image
-
OptiVISOR® Magnifier Available in diopters of: 3, 4, 5, 7, & 10 Ideal for anyone whose profession or hobby requires accurate work. Precision binocular headband magnifier permits unrestricted three-dimensional vision while reducing eye strain and freeing the hands. Optical glass prismatic lenses, ground and polished to precision optical standards. Visor can be worn over prescription or safety eye glasses. Pivots to allow visor to be tilted out of the way when not needed. Headband conforms to fit all head sizes, and is comfortable even when worn for long periods.
-
Optokinetic Drum - Adult White with Black Stripes Accurately test for acuity when rotated 8 to 10 RPMs at different reading distance. 10" long and 8" diameter. Item #: DAL300
-
Optokinetic Drum Ped 10 1/2' H x 8" Diameter Accurately test for acuity when rotated 8 to 10 RPMs at different reading distance. 10" long x 8" diameter Has Animals and Shapes Item #: DAL301
-
Accutome’s PachPen and PachPen Vet are the perfect combination of accuracy, portability and comfort. The superior ergonomic design fits comfortably in any hand, which is a major improvement from other handheld models.The PachPen is also equipped with Accutome’s Digital Signal Analysis which will eliminate non perpendicular measurements on the cornea.
-
The DM-21 Page Magnifier from Carson Optical is a deluxe rigid frame full page magnifier. It’s 2x power acrylic fresnel lens is sturdy and shatterproof. The Page Magnifier is perfect for reading large areas of small print such as maps, newspapers, directories, recipes and more. Simply hold the Page Magnifier 4 inches above the reading material for a clear view. The Page Magnifier is so thin you can store it in your reading material after use.
-
Our revolutionary PanOptic Ophthalmoscope addresses the fundamental challenge in ophthalmoscopy—to get a good view of the fundus in order to make a sufficient assessment. Patented Axial PointSource™ Optics make it easy to enter undilated pupils, offering a 25º field of view, resulting in a view of the fundus that's 5X greater than you see with a standard ophthalmoscope in an undilated eye. Direct viewing of the fundus through the PanOptic provides better images of the retinal changes caused by hypertension, diabetic retinopathy, glaucoma, and papilledema to enable clinicians to make these diagnoses earlier.
-
Paul Harris Randot Test (Special Edition) This test is recommended in lectures by Baltimore Academy for Behavioral Optometry. Special run by Stereo Optical exclusively for Bernell. Test down to 20 sec. Includes: Polarized Goggle
-
Sized to fit over our Adult Optokinetic Drum (DAL300) this vinyl sheet is used to test for the optokinetic reflex. The banner has child interest targets similar to our DAL301. Can be rolled up for easy storage. Clear end pieces hold banner from curling. Washable plastic material similar to window shade. Velcro on backside of the banner allows for easy attachment around the Adult Optokinetic Drum (DAL300). Item #: OKNADP1
-
Vectographic Projector Slide Pediatric Slide This pediatric projector slide test depth perception and binocularity under distance conditions. The top portion of each slide is a standard non-vectographic projector slide. The bottom portion is a vetographic slide that contains suppression control targets, a distance stereo acuity test, fixation disparity and binocular balance. Slide fits most AO and Marco projectors, and there are adaptable to a 10' or 20' lane. REQUIRES POLARIZING SCREEN.
-
A Hand Held instrument to Measure a Maddox Phoria. This tests for anisophorias, vertical and horizontal, in all positions of gaze in real space instead of behind of phropter. Scale from 0 to 10 PD 25mm Item #: BC1211
-
Copper Rod Ideal home training device for non-strabismics, esotropes with near centration point, and patients with other binocular vision problems. Three movable plastic beads on hand-held copper rod allows extensions of physiological diplopia techniques from 2" to 20'. Item #: BC1091
-
Physiological-Diplopia Cord™ (Similar to Brock String) Inexpensive home use instrument for near training as well as to extend phy-dip training from near into distance. Utilizes physical diplopia for training suppression, binocularity and spatial localization. Heavy cord with colored beads. Sold by the dozen in 10' or 20' lengths. Item #: BC109+
-
Plano Stick Prism Item #: ASPSPL
-
The PM-33 Pocket Magnifier™ from Carson Optical is a multi-power LED lighted Magnifier. This HandHeld Pocket Magnifier™ has three magnifying powers: 6x, 5x and 2.5x. It features a crystal-clear acrylic lens. It is an ideal low vision aide. The Pocket Magnifier™ is also perfect for reading fine print. It is so compact that it can easily fit in a pocket or purse.
-
Patented Welch Allyn Coaxial Vision optics, combined with 68 lenses in single-diopter steps, for the precision you need to conduct a quality eye exam.
-
Four-well flipper bar features two sets of lenses to alternate demand. Used with Tranaglyphs or Vectograms to reverse BI/BO demands. Item #: BC1270POL
-
This screening battery is designed to detet vision problems in the pre-school population. It includes a test for visual acuity, eye alignment, binocular funtcion, farsightedness, lazy eye (amblyopia), and more. Utilizing new test such as the school bus test, this screening test for a great number of problems in a short period of time. This screening battery of test was designed for use by school personnel of members of service clubs such as Lions or Kiwanis with minimal training. Many test are pass/fail
-
Pocket size cards for testing and evaluating non-readers. Seven different test targets printed on either side of 4 plastic cards with instructions on eigth side. Washable. Handy test for student clinicians and practicing professionals alike.
-
Flat prisms or Corrected Curved Prisms Professional training with two yoked prism pairs. Beginning with the highest powers through which a patient can fuse and focus, prism flippers are exchanged for the next higher powers through the training sequence. Great for early presbyopes with high exo with new bifocals! Please specify diopter power when ordering and if flat prism or corrected for abberations and made as thin as possible (corrected curved). Item #: BC1275+